WELCOME TO ECOTECH INSTRUMENTS. A hub of Ambient Air Quality Monitoring Instruments (PM 10 Sampler), Stack Emission Monitoring Instruments (Stack Sampler), Workers Exposure & Indoor Air Quality Monitoring Instruments (Personal Sampler), Meteorological Monitoring System (Automatic 16 Channel Weather Monitor With Sensors). Centre For Calibration Services:NABL (Certificate Number CC-2864).Calibration under NABL :Electro-Technical Calibration,Mechanical Calibration,Thermal Calibration,Fluid Flow Calibration. WINDROSE PLOT SOFTWARE.  

4 CHANNEL SPECIATION SAMPLER(ECOTECH MODEL AAS 406)

       
 
       
       
       
       
BACKGROUND
     

Detailed investigation of to composition of fine particulate matter present in atmosphere is necessary to understand the sources of high PM2.5/PM10 concentration in the atmosphere. Therefore, it is necessary to not only monitor concentration of PM2.5/PM10 mass but also required to determine the major chemical components of PM2.5/PM10 dust.

Since aerosol are typically made up of hundreds of different substances many of which are interacting with environment and also with one another. Investigation of aerosol chemical speciation has become a need for air pollution source apportionment studies for air quality management & control.

Speciation is two step sampling process of aerosol with filter-based sampler onto a specialized filter/pretreated cartridge followed by retrieval of samples and its analysis in lab using sophisticated analytical instruments.

FEATURES & SPECIALITIES:

Speciation sampler Ecotech Model AAS 406 is specially designed for collection of PM2.5/PM10 on to multiple 47mm dia filters followed by subsequent laboratory analysis of collected PM2.5/PM10 dust for different relevant chemical compounds including EC/OC, Trace Metals, Ions (Anions & Cations) Sulphates and Nitrates species.

AAS406 has 4 channel configuration where sampling flow rate of 16.67 lpm is maintained using Electronic pneumetic Mass Flow Controller at each channel independently. 4 channel speciation sampler offers unique advantage in ease of selecting any channels for PM10 or PM2.5. Filter of any kind can be used as per need. Its compact nature and ease of handling without compromising effective control on monitoring duration where all 4 samples are collected for same time exactly and simultaneously.

Each channel is provided with filter holder housing to place 47mm diameter PTFE filter/ Quartz filter / Nylon filter/Glass micro fiber/EPM2000 filter as per sampling protocol of specific chemical substances of interest. Provision also exists to fit Denuder for sampling of gaseous related species, as and when required. Flow control is taking place at 16.67lpm. Filter temperature is also recorded in logger continuously for all 4 channels. Sampler is fitted with new generation data logger which record internal data besides user defined input data for monitoring period.

Logger is provided with display to show important ongoing events and last recorded information. Logger has keypad for user programming & data retrieval using USB port and pen drive.

Logger has RS232 connectivity at which Laptop can be connected for parameter setting and for remote access of the data. Internet is needed at Laptop with operator to allow remote user to excess the logger data & setting through anydesk or Team Viewer. On each channel Microprocessor based Mass Flow with Pneumetic Flow Controller is provided.

Operation and event record and sampling performance parameters like Filter Temperature, Pressure, Volume, of air sampled, Elapsed time besides display of Ambient Temperature, Barometeric Pressure & Relative Humidity are monitored by in formal computer fitted in sampler.

Machine is automatically switched off if any of the following condition is arrive during sampling to safe guard the sample.

1. If flow rate is reduced beyond range of flow controller upto 10% for 5 minutes.

2. If difference in the ambient Temp and Filter Temperature is more than 50C for 5 minutes.

3. If filter pressure variation during sampling is more than 180 mmHg.

Coefficient of variation is computed for flow rate and recorded in logger for each channel.

Sensors for recording Temperature, R.H, & Barometric Pressure are provided and data are directly stored in Data logger at defined interval. Additional connector on card are also provided to connect ultrasonic W/S & W/D sensor. Standard unit is supplied without W/D, W/S sensor. Only ultrasonic W/S & W/D Sensor can be connected need to be oredred separately.

Ecotech product are designed to sustain harsh environmental condition of extreme Indian weather and dusty atmosphere.

A compatible laptop for data ownloading and management can also be supplied as per requirements (optional). This need to be ordered separately. Laptop supplied shall be loaded with 4 channel data handling software.

     
 
Our Customers
 
 
NABL Certificate and ISO Certificate
 
 

 
Ecotech Instruments
 
© 2022 Ecotech Instruments. All rights reserved
 
Home |About Us |Products |Services |Site Map |Contact Us
CPCB |NABL |NEERI |NPL | BIS |DOEn  
 

 
Designed and Developed by Horizon Information Systems